TimberLOK Screws 50 ea BOX


 

Directions

Installation Instructions: LedgerLOK should be installed using an impact driver or high torque 1/2 inches variable speed drill (minimum 18V if cordless). Choose the proper length fastener so that the threads fully engage the rim material. Bring the washer flush to the ledger - do not countersink. Not for use in concrete or masonry.

 

Description

3-5/8 in (92 mm). Replaces 1/2 inches lags. FastenMaster Lok Line. Meet code. Lower cost. LedgerLOK is engineered to attach the ledger board to the rim board of a house without predrilling. Guarantee Corrosion Resistance: LedgerLOK is guaranteed not to rust, streak or corrode for the life of the project. The coating on this fastener has been tested in wood treatment chemicals, such as ACQ, and found to provide equivalent protection to code approved hot-dipped galvanized coatings. LedgerLOK is not recommended for use in saltwater applications (within 1,000 ft). Fastening Patterns Deck Ledger to Rim Joist: Refer to FastenMaster's online technical bulletin for complete installation instructions. For applications other than the one listed above, a Professional Engineer (PE) may be consulted to determine proper connection design including the number and location of fasteners to meet local code and specific load requirements. Complete design values and engineering data available in our evaluation report, ICC-ES ESR-1078, available at www.FastenMaster.com. Fastening pattern for attaching deck ledger to rim joist using LedgerLOK: Maximum span between ledger and beam in feet: 6. LegerLOK spacing in inches: 24; Maximum span between ledger and beam in feet: 8. LegerLOK spacing in inches: 18; Maximum span between ledger and beam in feet: 10. LegerLOK spacing in inches: 14; Maximum span between ledger and beam in feet: 12. LegerLOK spacing in inches: 12; Maximum span between ledger and beam in feet: 14. LegerLOK spacing in inches: 10; Maximum span between ledger and beam in feet: 16. LegerLOK spacing in inches: 9; Maximum span between ledger and beam in feet: 18. LegerLOK spacing in inches: 8. The above table is an example of the most common patterns used to meet national code requirements but should not be the sole source to design this connection. Please refer to the Deck Ledger to Rim Joist Technical Bulletin on our website for detailed instructions including fastening patterns, minimum spacing requirements and restricted uses. Compliance audited by ICC-ES. No Predriling! Free hex drive bit code compliant. Desk ledger fastener.

Other Description

View a LederLOK installation video. For additional information or technical assistance, please contact FastenMaster Technical Support at 800-518-3569.

Warnings

Caution: Photographs on this package should not be used as a reference for fastening patterns.

UPC

00608309405627