Feit Electric Plant Grow Light 1 ea BOX
On This Page
Directions
Hanging Installation: 1. Slide S-hook at the end of 6 inch wire harness assembly into slot on utility light. 2. Mark location on ceiling for eyelet screws (not included) using screw hole template (on box side panel) to hang loop on wire harness assembly. 3. Slide loop on wire harness assembly around eyelet screw cap. Flush Mount and Ceiling Installation: 1. Mark screw holes with template (on box side panel). 2. Mount flush mount screws (included). 3. Align screws holes on utility light with screw heads, slide over to lock in place.
Description
Red spectrum enriched for budding & flowering. Emits spectrum wavelengths and color for photosynthetic response. Rated for high humidity use. Emits more light in the useful 450 nm blue and 641 nm red spectrum than regular white LED bulb. Low heat emission and low energy consumption. Cooler operation than HPS lamps to guard against leaf burn. No humming. Light weight design. No lamps to dispose or replace. 5 ft plug-in cord. Includes 6 inch hanging wire harness. Hang or flush mount installation. Low amount of heat. 25,000 life hours. Linkable up to 3 fixtures. Suitable for hydroponic growing. Easy plug-in use. With on/off rocker switch. Using Grow Lights: Why Use LED Grow Lights: Grow plants during the winter for a head start on spring vegetable plants. Grow plants that are out of season throughout the year. Grow plants anywhere including garages, basements, closets, kitchens or warehouses. Benefits of Supplemental Lighting: Use of a supplement light source including LED lighting can have an impact on: fruit number; fruit weight; stem (diameter/length); leaf length; shoot dry weight; bud size; leaf size; sweetness; acidity; texture; color. Recommended Light to Plant Distance: Plant types are generally categorized into high or low light level plant categories. The PAR value of a plant light equates to the amount of light energy that a plant can absorb. The higher the PAR, the more intense the light energy a plant can absorb facilitating accelerated vegetative and/or flowering growth. Below are the plant types and recommended optimal light energy absorption distances based on this LED grow light. Hydroponic Grow Light: 16-30 inch. Coverage: One 2 ft grow light will cover an area ot 2 feet by 2 feet. High Light Plants: i.e. cannabis, tomatoes, peppers, perennials, etc. Seedings stage - 6 inch thru 2 weeks of vegetative stage and/or flowering stage = 16-30 inch. Low Light Plants: i.e. herbs and leafy greens (such as basil lettuce). Seedings stage - 12 inch thru 2 weeks of vegetative stage and/or flowering stage 24-30 inch. Optimal growth layout. Full spectrum grow light. Hang or flush mount. Hydroponic grow light. The Feit Electric full spectrum and hydroponic lights can both either hung or flush mounted above the plant. For optimal light absorption of flowering & budding plants, it is recommended to hang or flush mount the full spectrum above the plant and mount/position the hydroponic lights shining inward on either side of the plant mounted to any structure. Notes: All information provided should be used only as a suggestion. No expressed guarantees of plant health or growth are guaranteed or implied with the use of these lights. Variables such as soil, water, humidity, temperature and other factors will impact all plants health. Plants in Vegetative Growth Stage: The recommended growth cycle is 18 hours of light during the vegetative growth stage. This light cycle will create an environment that mimics the photoperiod in the summer with long days. It is during the vegetative growth stage that cloning, transplanting, pruning, and bending are all initiated. Turn your LED grow light on for 18 hours a day and then turn the light off and leave your plant in the dark for another 6 hours. Most plants will need four to six weeks in the vegetative cycle before reaching the start the flowering stage. Plants in Budding and Flowering Growth Stage: Pre-flowers are the first indication that the plant is ready to move into the budding and/or flowering stage of growth. The pre-flowers grow at branch internodes just behind the leaf spur typically around the fourth week of vegetable growth, when the plant is six to eight weeks old. When you start seeing pre-flowers forming this means that the plants are ready to go into the flowering stage. You can continue to grow in the vegetative growth stage or switch to flowering at this point. The pre-flower looks like a regular female flower with white fuzzy pistils. The pre-floering can take from one to two weeks. Wait to induce flowering until pre-flowers have appeared. Induce flowering by switching your light cycle to 12 hours of uninterrupted darkness and 12 hours of light. Notes: If LED grow light is installed as flush mount texture under a cabinet or canopy where distance cannot be adjusted, mount at the min of 24 inch distance. If LED grow light can be hung from a ceiling, cabinet or canopy, use the supplied hanging assembly or purchase separately a chain to adjust height of LED light to maintain the recommended distances as the plant grows. For taller plants including tomatoes and cannabis, mounting one (1) grow light overhead and one (1) grow light as a side light on either side of the plant will provide additional supplement light supporting plant growth for a busty plant. Lighting Summary: Brand: Feit. Lamp Type: LED. Voltage (VAC): 120. Current (A): 0.5. Power (W): 60. Photon Flux (mcmol/s): mm Range (mcmol/s): 400-499: 14.39. 500-599: 4.99. 600-699: 48.94. 700-799. Total: 68.32. PAR (mcmol/s): 68. PAR Efficacy (mcmol/J): 1.1. PAR Efficacy (mcmol/kWh): 4.1. Luminous Flux (lm): 1900. CCT (K): 1300. CRI (Ra): None. Red and blue ends of the visible part of the electromagnetic spectrum are used by plants in photosynthesis. Chlorophyll a - a & b are the primary pigments for photosynthesis in plants with absorption peaks at approximately 450 nm and 630 nm.Other Description
For more information visit www.feit.com or call our toll free number 1-866-326-BULB.Warnings
Caution: Use only on 120 volt, 60 hz circuits. Minimum starting temperature - 10 degrees C (14 degrees F). This device is not intended for use with emergency exit fixtures or emergency lights. Do not use with dimmers. When installing, make sure that power is switched off before connecting or disconnecting to fixture. Do not look directly into the light. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. The performance specifications (lumens, watts, life, and CCT) printed on this product package should be only be considered an approximation of expected performance.UPC
00017801743753